+57 (7) 6158035 - 6158036 - 310 2098850Hours of operation: Mon to Fri 7:30am to 12:00pm - 1:00 to 5:00pm Sat 8:30am to 12:00pm

RAMCO® OnGuard™: Acid and Base Leak-Detecting Paint for Industrial Pipeline Integrity

RAMCO® OnGuard™: Acid and Base Leak-Detecting Paint for Industrial Pipeline Integrity

RAMCO® OnGuard™: Acid and Base Leak-Detecting Paint for Industrial Pipeline Integrity

Introduction

In industrial plants where acids and bases are handled —refining, petrochemical, fertilizer, mining and naval industries— an undetected leak can escalate within minutes into a catastrophic event: personnel injury, loss of containment, unplanned shutdown and environmental impact. Early detection, before the leak becomes visible or significant, is one of the least addressed pillars of mechanical integrity management.

RAMCO® OnGuard™ responds precisely to this challenge: an industrial paint that changes color upon contact with acids or bases, transforming flanges, valves and pipelines into permanent visual sensors, without requiring electronic instrumentation or electrical power.

What is OnGuard™?

OnGuard™ is an industrial coating developed by RAMCO® Manufacturing Co., Inc. (Houston, Texas) with a pH-sensitive component that reacts to the presence of acids (pH ≤ 3) or bases (pH ≥ 10), producing an immediate color change that is visible from a distance.

The system includes two complementary versions:

  • OnGuard™ Acid Detecting Paint: Modified acrylic alkyd coating, lead-free. Its base color is golden yellow and it turns bright red when exposed to acids or acid vapors with a pH of 3 or lower. The reaction is instantaneous.
  • OnGuard™ Base Detecting Paint: Water-based coating (latex), formulated as an alkaline indicator for solutions with a pH of 10 or higher. The film cures white and changes to an indicator color upon exposure.

A differentiating feature of the system is its reversibility: once the leak has been isolated and repaired, the surface only needs to be rinsed with water or a mild alkaline solution for OnGuard™ to return to its original color and become ready to detect future events again, without the need for repainting.

Benefits of the OnGuard™ system

The system stands out for the following benefits:

  1. Immediate visual indication of leaks: even in quantities too small to activate conventional gas or pH sensors.
  2. Reversibility without repainting: after cleaning with water, the coating recovers its base color and becomes operational again.
  3. Detection without electronic equipment: it does not require electrical power, periodic calibration or instrumental maintenance.
  4. Lead-free: fully organic formulation for the acid version and water-based formulation for the base version.
  5. Compatible with RAMCO® #315 white primer: recommended to maximize chromatic sensitivity and prevent system lifting.
  6. Applicable by brush, roller or conventional or airless spray: with a maximum dilution of 5–10% in acetone if required.
  7. Recommended dry film thickness: 4 mils, equivalent to 2–3 coats, with a coverage of 200–250 ft² per gallon.
  8. Shelf life in sealed container: 1 year under controlled storage conditions.
  9. Works as a complement to existing anticorrosive systems: adding a safety layer without modifying the original protection scheme.

How does the color change work?

The active component of the coating contains a chemical indicator that reacts to the concentration of H⁺ ions (acids) or OH⁻ ions (bases). When a leak occurs —for example, in a flange gasket, a valve thread or a weld bead— the chemical substance comes into contact with the cured film and the indicator changes its structure, generating the color shift.

The reaction is instantaneous when exposed to acids with pH ≤ 3, such as sulfuric, hydrochloric, nitric or hydrofluoric acid, and allows the exact source of the leak to be identified, not just its general presence in the area. This drastically reduces the response time of operations and maintenance personnel, preventing a minor event from escalating into a major incident.

Typical property tests

  1. Acid sensitivity: Color change by exposure.
    Typical value: pH ≤ 3 (golden yellow → bright red)
  2. Base sensitivity: Color change by exposure.
    Typical value: pH ≥ 10 (white → indicator color)
  3. Reversibility: After rinsing with water.
    Typical value: Returns to base color, without repainting.
  4. Recommended dry film thickness: DFT (Dry Film Thickness).
    Typical value: 4 mils (2–3 coats)
  5. Coverage: Practical application.
    Typical value: 200–250 ft²/gallon
  6. Surface preparation (steel): SSPC-SP2 / SSPC-SP3.
    Typical value: Manual cleaning or power tool cleaning
  7. Dilution: Acetone.
    Typical value: Up to 10% for air spray / 5% for airless, brush or roller
  8. Storage temperature (acids): Min. / Max.
    Typical value: -7 °C to 43 °C
  9. Storage temperature (bases): Min. / Max.
    Typical value: 4 °C to 43 °C (protect from freezing)
  10. Application equipment:
    Typical value: Conventional spray, airless spray, brush or roller
  11. Shelf life in container: Factory-sealed container.
    Typical value: 1 year

Critical sectors and applications

OnGuard™ is designed for surfaces and connections where even a minimal leak represents a critical safety, environmental or operational risk. Typical applications include:

  • Flanges, valves, pumps and tanks
  • Sampling ports and flow indicators
  • Expansion joints, clamps and hose connections
  • Weld points and weld beads
  • Threaded connections
  • Tank truck domes and rail tank cars
  • Heat exchangers, pressure vessels and instrumentation

The sectors where OnGuard™ provides the greatest value are those where Aplika already has a consolidated presence:

  • Oil & Gas: alkylation units (HF, H₂SO₄), refining, sour gas treatment.
  • Petrochemical: plants for the production of mineral acids and derivatives.
  • Fertilizers: handling of sulfuric, phosphoric and nitric acid, and ammonia.
  • Mining: acid leaching (copper, gold), hydrometallurgical processes.
  • Water treatment and sanitation: systems with acid and base dosing for pH control.
  • Naval and offshore industry: power generation plants, auxiliary systems, storage areas.

Surface preparation and application

Surface preparation is decisive for the chromatic performance of the system. On steel, manual cleaning SSPC-SP2 or power tool cleaning SSPC-SP3 is recommended as a minimum, ensuring that the surface is clean, dry and free of rust, dust, grease and contaminants.

For maximum chromatic sensitivity, the application of RAMCO® #315 white primer as an intermediate layer is strongly recommended. OnGuard™ may be applied over existing paints as long as the substrate is stable and properly prepared; applying it over inferior or unstable coatings may cause lifting of the layers.

The target thickness is 4 mils dry, typically achieved with 2–3 coats applied by brush, roller or spray. After application, the drying time between coats must be respected according to the environmental conditions of the site.

Integration with the Aplika portfolio

OnGuard™ does not replace the main anticorrosive coating system: it complements it as a detection system. The recommended technical strategy is to apply it selectively on critical leak points —flanges, valves, threaded connections and sampling points— once the main anticorrosive coating, such as Scotchkote™, high-performance epoxy systems or other solutions from the Aplika portfolio, has already been applied and cured.

This combination allows plants to:

  • Reduce leak detection time from hours to seconds.
  • Decrease the risk of personnel exposure to hazardous substances.
  • Comply with international mechanical and process integrity standards (AMPP/NACE, API, ASME PCC-2).
  • Optimize the frequency of scheduled visual inspections and shutdown planning.

Conclusion

The protection of a critical asset does not end with the application of an anticorrosive coating: true integrity management includes detecting, on time, the events that may compromise operational and environmental safety. RAMCO® OnGuard™, integrated into the technical scheme designed by Aplika for each plant, turns every flange, valve and connection into an active monitoring point.

Protecting your critical assets begins with making the right technical decision.

Specialized technical advisory

Are you evaluating the incorporation of a visual leak detection system in your plant?

Aplika’s technical team can advise you on the selection, supply and supervision of the application of OnGuard™ together with the most suitable anticorrosive system for your operating conditions.

Request a technical assessment

Technical contact: +57 310 209 8850

Email: gerencia.tecnica@aplika.com.co

Tags

Share post